Guide

How to choose a manifold cassette size by the number of circuits

Published: Updated: 2 min read

Short answer

Count the heating circuits, then measure the whole manifold assembly — outlets, ball valves, end fittings and any pump or mixing group — and add room for the pipes to bend. The right cassette is the smallest one whose inside width and depth are larger than that assembly. Our sizing tables give the model for 2 to 16 circuits.

Why is the number of circuits not enough on its own?

Because two manifolds with the same number of circuits can differ in width by several centimetres. The circuit count is the starting point; the manifold’s own dimensions decide the cassette.

Outlet spacing, the type of ball valves on the flow and return, end pieces with air vents and drain cocks, and flow meters or actuators all add width, height or depth. A manifold with a pump or mixing group needs much more room than a plain one.

How do I measure the manifold assembly?

Measure it as it will be installed, with everything mounted:

  1. Width — from the outer end of the ball valves to the outer end of the end fittings.
  2. Height — from the top of the flow meters or actuators to the bottom of the lowest outlet.
  3. Depth — from the wall to the front of the actuators or flow meters.

If the manifold has not arrived yet, take the dimensions from its datasheet.

How much extra room do the pipes need?

Enough for the pipes to come up from the floor and bend into the outlets without kinking, plus some space at the sides for hands and tools. In practice that means choosing a cassette whose inside dimensions are comfortably larger than the manifold, not one that only just fits. When you are between two sizes, take the larger one.

Which cassette fits how many circuits?

Each product page has a table with the model and outer dimensions for every circuit count from 2 to 16:

The sizing tool on the homepage does the same in two clicks.

What if there is a pump or mixing group?

Then the cassette has to be wider and often deeper, because the pump and the mixing valve sit beside the manifold. Send us the model of the pump or mixing group and we recommend the size.

What should I send if I am not sure?

The manifold model or its datasheet, the number of circuits, flush or surface mounting, and the wall depth you have. We check the fit and reply with the model — through the quote form or by phone.

Common questions

How do I choose a manifold cassette size by the number of circuits?

Start from the number of heating circuits, then measure the whole manifold assembly: outlets, ball valves, end fittings and any pump or mixing group. Choose the cassette whose inside width is larger than that assembly, with room for the pipe bends. Our sizing table lists the right model for 2 to 16 circuits.

My manifold is between two cassette sizes — which one should I take?

Take the larger one. The pipes need room to bend from the floor into the manifold without kinking, and the extra width makes connecting the valves and actuators easier. If the larger cassette does not fit the wall, we can make an intermediate width to order — send us the manifold model and the wall dimensions.

Does a pump or mixing group fit inside the cassette?

It can, but it needs a wider and often deeper cassette than the manifold alone, because the pump and mixing valve sit beside the manifold. Tell us which pump or mixing group you use, or send its datasheet, and we recommend a cassette with enough room.

All questions

Tell us the number of circuits — or send a drawing

We reply with the right model, dimensions and price, in Macedonian, Albanian or English.